1. SAFETY WARNINGS
The product must be installed by a qualified engineer, according to the local safety standards and
regulations.
The product is classified as Class II, in accordance with EN 60065, and for this reason it doesn’t
need to be connected to the protective earth (PE) of the mains supply.
Installation warnings
• Only use the original power cable (adaptor) supplied and install the product so that the mains
plug is easily accessible.
• The product must not be exposed to dripping or splashing liquids and so must be installed
indoors in a dry place.
• Humidity and condensation could damage the product. In case of condensation, wait until
the product is dry before using it.
• Don’t install the product above or close to heat sources, in dusty places or where it might
come into contact with corrosive substances.
• Keep the product away from heat sources to prevent some parts or components of the unit
to catching fire.
• To fix the product to the wall use suitable expansion bolts.
• Leave enough space around the product housing to ensure sufficient ventilation.
“An excessive operating temperature and/or excessive heat may affect the performance
and the lifespan of the product.”
• Never look inside the product’s optical connectors. The laser radiation is not visible with the
naked eye and therefore it is not possible to prevent long term damage.
• When working with the splitter’s optical connectors make sure that the lasers of any optical
transmitters connected to it are switched off.
• In accordance with the European Directive 2004/108/EC (EMC), the product must be
installed using devices, cables and accessories that comply with this directives requirements
for fixed installations.
Aerial system earth connection
The unit must be connected to the ground electrode of the antenna installation according to
the standard EN60728-11. We recommend following the provisions of standard EN60728-11
therefore not connecting the ground electrode to the earthing of the power supply network.
IMPORTANT:
Only trained and authorised personnel can open the product. In case of failure, do not try to repair
the product; otherwise the guarantee will no longer be valid.
INVISIBLE LASER RADIATION
DO NOT VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
(MAGNIFIERS)
CLASS 1M LASER PRODUCT
LASER RADIATION